Items |
LPC420 Din Rail Mount Level Probe Converter |
LPC420-RM Reverse Mount Level Probe Converter |
||
Supply Voltage | N/A 24 VDC | |||
Supply Voltage Tolerance (±) | N/A 10 % | |||
Maximum Supply Current | N/A | N/A 65 mA | ||
Maximum Power Consumption | N/A 1.8 Watt | N/A | ||
Non-Isolated Analog Output Current (Transient Protected) | N/A Non-Isolated, 4-20 mA | |||
Analog Output Maximum Load | N/A | N/A 600 O | ||
Sensor Output Voltage | N/A ± 8 V Square Wave | N/A ± 8 V Square Wave at 60 Hz | ||
Sensor Output Current | N/A ± 0.8 mA max (per sensor) | |||
Operating Temperature | N/A -20 to +65 ºC | |||
Storage Temperature | N/A -45 to 85 ºC | |||
Enclosure Material | N/A Din Rail Mounted Aluminum | N/A Panel Mounted Aluminum | ||
Additional Description | N/A | N/A The Analog Output Delay setting provides control over how fast the analog output transitions from one level output value to another. It takes 10 times the Analog Output Delay setting value to go from 4 to 20 mA, when the electrodes are covered quickly. When the electrodes are slowly covered one at a time, the Analog Output Delay is used to provide a smooth transition as the level goes from electrode to electrode. | ||
Typical Applications | N/A | N/A For use with any 10 electrode conductance probe where an analog 4 to 20 mA level signal and a panel mounted level display are required. | ||
|