Product Video |
N/A |
Underwriter's Laboratories (UL) File Number |
N/A #E101681 |
Product Type |
N/A Pump Monitor Relay |
Maximum Input Power |
N/A 7.0 V·A |
Alternating Current (AC) Input Voltage |
N/A 120 V |
Input Voltage Tolerance (±) |
N/A 10 % |
Output Rating at 120 Volt Alternating Current (AC) Voltage |
N/A 8A Resistive |
Operating Temperature |
N/A -20 to +65 ºC |
Storage Temperature |
N/A -45 to 85 ºC |
Temperature Sensor Voltage |
N/A 6.6 VDC ±10% |
Leak Sensor Voltage |
N/A 4.7 VAC ±10% |
Enclosure Material |
N/A White Lexan |
Base Material |
N/A Phenolic |
Additional Description |
N/A
The PMR1 applies a low voltage DC signal to the Motor Thermal Sensor to check its status, and uses a low voltage AC signal to measure the resistance between a single (or dual) Leakage Probe(s) and the grounded motor housing, or between two Leakage Probes to check for the Seal Leakage condition. The PMR1 has two mounting options and comes with an 11 pin reverse socket for dead front mounting. |