• Sump and Sewage Pump Exerciser® Controllers for Piggy-Back Float Operated Pumps

    The Exerciser® reads the state of the Float Switch and turns the pump ON when the Float Switch closes, and turns the pump OFF when the Float Switch opens. If the pump has not run for 7 days, The Exerciser® will automatically exercise the pump for 3 seconds. The 7 day exercise time delay is reset each time the pump is called to run by the Float Switch.

    The Exerciser® also detects if a foreign object is keeping the pump from turning freely by monitoring both the motor inrush current and the motor run current. If The Exerciser® detects a fault condition, it turns the pump off, turns on the audible alarm, flashes the Run/Fault LED, and closes the alarm relay contact. One minute after a fault condition is first detected, The Exerciser® will again attempt to start the pump. If the fault is detected the second time, The Exerciser® wait one more minute and then try a third time to start the pump. If the pump starts and runs normally, the fault history clears after thirty minutes. If the pump fails to start and run the third time, the fault condition remains present until the reset button is depressed.

    The Test/Reset push-button has two functions: If there is no fault present, pressing the button will start the 3 second Pump Exercise cycle, and reset the exercise time delay for 7 more days. If a fault alarm is present, pressing the button will silence the buzzer and reset the alarm, allowing normal operation. (Assuming that the pump is free of any obstruction.)

    The SPEX-1 is a simple home alarm system for basement protection. With the sump pump alarm contact it is also the perfect fit for truck loading docks, elevator sump areas, and dry pit sump areas.

    Reminder: Always unplug pump from Exerciser® when inspecting pump.

  • Sump and Sewage Pump Exerciser® Controllers for Integral Float Operated Pumps

    The Exerciser® reads the state of the Float Switch and turns the pump ON when the Float Switch closes, and turns the pump OFF when the Float Switch opens. If the pump has not run for 7 days, The Exerciser® will automatically exercise the pump for 3 seconds. The 7 day exercise time delay is reset each time the pump is called to run by the Float Switch.

    The Exerciser® also detects if a foreign object is keeping the pump from turning freely by monitoring both the motor inrush current and the motor run current. If The Exerciser® detects a fault condition, it turns the pump off, turns on the audible alarm, flashes the Run/Fault LED, and closes the alarm relay contact. One minute after a fault condition is first detected, The Exerciser® will again attempt to start the pump. If the fault is detected the second time, The Exerciser® wait one more minute and then try a third time to start the pump. If the pump starts and runs normally, the fault history clears after thirty minutes. If the pump fails to start and run the third time, the fault condition remains present until the reset button is depressed.

    The Test/Reset push-button has two functions: If there is no fault present, pressing the button will start the 3 second Pump Exercise cycle, and reset the exercise time delay for 7 more days. If a fault alarm is present, pressing the button will silence the buzzer and reset the alarm, allowing normal operation. (Assuming that the pump is free of any obstruction.)

    Reminder: Always unplug pump from Exerciser® when inspecting pump.

  • Simplexer Controllers - 161017

    The Simplexer Controller (010-120-121P) is a plug-in controller for single pump control operation. The controller’s inputs shall be designed to accept either float switches or a conductance level probe input. The Simplexer Controller shall be UL508 Listed, SCADA ready, with modbus protocol, and be able to perform either pump-up or pump down control.

  • Duplexer Controllers (161017)

    The DUPLEXER (010-120-122P) is a low cost SCADA ready, Modbus RTU Protocol plug-in pump controller designed to perform level control for duplex lift station applications. The level inputs of this dual pump controller can be connected to either four float switches or to a conductance probe. This 2 pump controller provides a 10 second power-up start delay, 5 second lag pump delay, and duplex alternation. LEDs provide power on status, level input status, pump call status, and high level alarm status indication. Pump 1 & 2 call and high level alarm relays are provided. HOA and lead select toggle switches are also provided.