The SC5000 is a Six Pump Controller with Five Control Modes capable of performing:

Level Control

Flow Control

Pressure Control

Booster Discharge Control

Booster Supply Control

The five Control Modes are menu selectable and within each Control Mode there are a variety of control options in the setup menu that make the Controller customizable for a large number of applications.

The SC5000 comes with a door mounted HMI, either a Color Touch Screen HMI or a 5 Digit Numerical LED HMI. The HMI makes the Station Status and Setup Parameters readily available to the operator. Dedicated Communication Ports ENET2 or COM1 are provided for connection to the HMI.

A din-rail mounted 24VDC Power Supply is also provided with the Controller.

The Controller alternates the pumps, performs Lag Pump Delays, provides High and Low Level, Flow Rate or Pressure Alarms and many other optional features. It has parameters in the menu that allow the operator to set the Number of Pumps Present, the Maximum Number of Pumps Allowed to Run At the Same Time, and the Maximum Number of Pumps Allowed to Run While On a Generator.

With up to 6 optional Analog Outputs it can also perform VFD speed control.

While the SC5000 functions as a stand alone Pump Controller, it is designed to be easily integrated into a SCADA System. Ethernet Port ENET1 (with Modbus/TCP) is provided on all units for connection to a SCADA system. All units come with 30 Discrete Inputs that may be used to collect discrete telemetry. All units come with 12 Output Relays, any of which can be setup to perform remote control functions. Also available are 8 optional Analog Inputs and 3 optional Pulse Type Flow Meter Inputs for the collection of data. Parameter Security can be enabled to protect the Controller Setup and Remote Control Parameters from being remotely tampered with. The Modbus Registers for all Setup, Status and Remote Control Parameters are fully documented in the manual.

The Controller comes with a USB Host Port for Backup and Restore of Setup Parameters. 

1 - 1 of 1 | Results Per Page | View | Unit of Measure
1 

Item #

List Price

Number Of Analog Inputs

Number of Analog Outputs

Underwriter's Laboratories (UL) File Number

Supply Voltage

Supply Voltage Tolerance (±)

Agency Approval

Pulse Capture Inputs

Ambient Operating Temperature

Isolated Analog Input Current (Transient Protected)

Isolated Analog Output Current

Dimensions

Relay Output at 120 Volt Alternating Current (AC) Voltage

Discrete Inputs

Customer Options

Add To Cart/Request Quote
Quote N/A 2 N/A 1 N/A # E101681 N/A 24VDC N/A 10 % N/A CAN/CSA UL 508 N/A Isolated, Transient Protected Maximum Pulse Frequency: 60kHz (with Duty Cycle Between 40% - 60%) Power Supply Options: +5VDC, +12VDC, or +24VDC Pull Up or Pull Down Resistor Supplied with Controller: 5.1 KO N/A -20 to +65 ºC N/A Isolated 4-20mA, 100 Ohm Load, Transient Protected N/A Isolated 4-20mA, Transient Protected, Maximum Load: 900 Ohm N/A 10.340” x 6.750” x 6.208” N/A 8 A N/A ±6V, 60Hz Square Wave ±0.6mA max, Transient Protected N/A Add To Cart
Request Quote