If you don't find what you are looking for, please call MPE at 407-299-3825.
View Cart View RFQs Express Ordering
 Shopping Cart 0 Items
 Request for Quote 0 Items
All Categories > Controllers > SC2000E Station Controllers > Item # SC2000-22E  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Add To Cart Request Quote

Item # SC2000-22E, 2 Analog Output and 2 Auxiliary Analog Input Station Controller



The SC2000E Station Controller is a panel mount SCADA ready, Modbus RTU Protocol, pump controller designed to perform level control in a wide range of lift station applications, including Level Pump Down/Pump Up. The SC2000E level controller operates the pumps based on the selected setup values and the wet well level signal. The level input source is menu selectable for either a 4-20 mA pressure transducer, or a conductance probe. The SC2000E alternates the pumps, performs lag pump delays, and provides high and low level alarms. The SC2000E has a variety of control options available in the setup menu that may be used to customize the controller for a specific application. Optional I/O is available for VFD speed control and for additional telemetry inputs. Connecting the RS-232 serial port (or optional Ethernet Port) to a SCADA system allows the lift station to be monitored and controlled remotely. The SC2000E can be configured as either a single speed control or VFD.






Specifications  · Typical Applications  · Features

Specifications

Underwriter's Laboratories (UL) File Number

#E101681

Product Type

SC2000, 4 Pump Level Controller

Number of Analog Outputs

2

Number of Auxiliary Analog Inputs

2

Maximum Input Power

13.0 V·A

Input Voltage

120 VAC, ± 10%

Input Voltage Tolerance (±)

10 %

Electromagnetic Interference (EMI) Line Filter

Pie Type

Input Power Transient Protection

Metal Oxide Varistor

Agency Approval

CAN
CSA

UL 508

Ambient Operating Temperature

-20 to +50 ºC

Level Display

5 Digit, 7 Segment LED

Level Display Range (Decimal Point Position Selectable)

0 to 2310 ft

Display Indicator

LED's

Color

White with Blue Lettering

Aux. Analog Inputs

Isolated 4-20 mA, 100 ohm Load, Transient Protected

Discrete Inputs

Optically Isolated and Transient Protected

Power for Discrete Inputs

24 VDC, Unregulated, Transient Protected

Power for Analog Input

20 VDC, ± 1%, Regulated

Regulated Direct Current (DC) Voltage Tolerance (±)

1 V

Isolated Analog Output Current

4-20 mA, max load 900 ohm, Transient Protected

Maximum Analog Output Load

900 O

Isolated Analog Input Current (Transient Protected)

4-20 mA, 100 ohm Load, Transient Protected

Isolated Auxiliary Analog Input Current (Transient Protected)

4 to 20 mA

Auxiliary Analog Input Load (Transient Protected)

100 O

External Height

6.9 in

External Width

8.5 in

External Depth

4.9 in

Cut Out Height

6.0 in

Cut Out Width

7.5 in

Options

Add "-S" to part number for an Isolated Analog Level Input

Category

Controllers

Relay Current at 120 Volt Alternating Current (AC) Voltage

8 A


Typical Applications

Duplex Pump Control



Fixed Speed Control



Pump Down (Empty a Tank)



Pump Up (Fill a Tank)



Quadraplex Pump Control



Simplex Pump Control



Triplex Pump Control



Variable Speed Control





Features
  • All Setup Parameter Values May be Viewed or Changed From the Front of Unit
  • 120 VAC input power
  • Level Input Source - Menu Selectable
  • Analog Level Input (4-20 mA)
  • Level Probe (Conductance Probe with 10 Inputs)
  • 20 VDC Power for Analog Level Input Loop
  • 6 Amp Relay Outputs for: Pump Call, High Level, and Low Level Alarms
  • RS-232 Serial Port, Modbus RTU Protocol
  • Alternation Modes - Menu Selectable
    • Standard Alternation
    • Pump 1 Always Lead - Stays On with Other Pumps
    • Pump 1 Always Lead - Turns Off with Other Pumps On
    • Split Alternation - Pumps 1 & 2, and Pumps 3 & 4
    • Fixed Sequence - Pump 1 Always Leads
    • Stepped On/Off - Only One Pump Runs at a Time
  • Alternation - First On - Last Off or First On - First Off
  • Alternator Logic Skips Disabled Pumps
  • Remembers Lead Pump Position During Power Outage
  • Timed [1 minute] Level Simulation
  • Security Code Protected Parameter Setup
  • 18 Discrete Inputs that can be Programmed for the Following Functions :
    • Pump Disable with HOA in OFF, or Pump Fault
    • External Alternator Selector Switch
    • All Pump Disable - for Connection to Phase Monitor
    • Limit Number of Pumps Called While on Emergency Power
    • Alternation by External Time Clock
    • Freeze Wet Well Level During Bubbler Tube Purge
    • Call Pump Last - for Connection to VFD/Bypass Logic
    • Float Switch Backup
    • A Variety of Telemetry Functions
  • Status of Discrete Inputs May Be Viewed From Front of Controller
  • Plug In style Connectors
  • Wetwell Flush Cycle Feature to reduce sludge build-up within the wetwell
  • Flow Calculator Feature for latest Inflow Rate, Average Daily Flow, and Pump Outflow Rate
  • Unused Output Relays programmable via SCADA for additional control uses




 DOWNLOADS 

Instruction Manual for SC2000E Station Controllers
(PDF, 2697KB)

Product Data Sheets - SC2000E Station Controllers
(PDF, 453KB)

MPE SC2000 Station Controllers Specification
(PDF, 92KB)


Add To Cart Request Quote
Site created by Thomas Web Solutions and powered by Navigator Platform
Motor Protection Electronics, Inc. | Leaders in Design and Manufacturing for Industrial Controls